PlasmaTact is an atmospheric pressure gas plasma system. It can be used for various surface treatments. Atmospheric pressure plasma technology can perform surface modification processes for bonding, cleaning, or activating the materials.

キービジュアル

Feature

1/ 2/ 3

Atmospheric pressure

PlasmaTact generates plasma under atmospheric pressure.
It is a compact and portable atmospheric pressure plasma equipment, eliminating the need for expensive and cumbersome vacuum-related equipment.

Argon gas

Argon gas is an inert monatomic molecule.
PlasmaTact generates argon gas plasma.
Using argon gas suppresses ozone and NOx.

Microwave method

Typically, plasma is generated at low frequency, at high voltage.
PlasmaTact uses 2.4 – 2.5GHz microwave.
This enables low-voltage, low-temperature plasma irradiation.

Feature

01/ 02/ 03

Atmospheric pressure

Argon gas

Microwave method

PlasmaTact generates plasma under atmospheric pressure.
It is a compact and portable atmospheric pressure plasma equipment, eliminating the need for expensive and cumbersome vacuum-related equipment.

Argon gas is an inert monatomic molecule.
PlasmaTact generates argon gas plasma.
Using argon gas suppresses ozone and NOx.

Typically, plasma is generated at low frequency, at high voltage.
PlasmaTact uses 2.4 – 2.5GHz microwave.
This enables low-voltage, low-temperature plasma irradiation.

Process Data

PlasmaTact uses plasmaized argon gas to modify the surfaces of thermoplastic and thermosetting resins, metals, and glass from hydrophobic to hydrophilic.
It is expected to be applied to pretreatment of difficult-to-adhere materials and cleaning of organic materials.

Al/ PEEK/ ABS/ PP/ PI/ Silicone rubber

material Before After
Al 88.0° 26.3°
PEEK 89.4° 22.6°
ABS 89.2° 13.0°
PP 98.9° 40.8°
PI 71.0° 12.2°
Silicone rubber 111.6° 5.7°
Epoxy resin 83.3° 18.9°
Glass 56.6° 4.8°
LCP 95.7° 19.5°
PA12 87.3° 22.0°
PBT 92.1° 32.4°
PC 86.0° 40.3°
PE 93.6° 14.2°
PEI 81.0° 18.8°
PES 76.5° 25.2°
PET 78.5° 18.1°
Phenol resin 87.0° 18.8°
POM 91.0° 59.6°
PPA 70.5° 36.7°
PPS 80.0° 30.7°
PPSU 85.7° 18.8°
PS 88.9° 14.2°
PVC 76.5° 33.3°
SiO2 glass 15.9° 4.3°

Specification

Model Name PLT-50
Frequency Range 2400 - 2500MHz
Output Power Range 10 - 50W (1W steps)
Gas Flow Rate Main gas:5.0slm - 10.0slm
(0.1slm steps)
Power Source 100 - 220V ±10% 50 - 60Hz
Power Consumption Single phase 350VA
External Dimensions (W)323 × (L)400 × (H)177 (mm)
Protruding parts not included
Weight Approx. 16kg/35lbs

Structure

Control unit

This unit controls gas flow rate and plasma power. It can be operated with the buttons on the front panel. A remote control interface is also provided.

Plasma torch

Plasma is generated with this unit. Atmospheric pressure plasma is ejected from 2mm diameter nozzle. Surface modification of a 12 mm diameter area is possible. (Depends on gas flow rate, power input, irradiation distance, and irradiation time).

Catalog

Medical

This atmospheric pressure plasma technology is also used in medical devices.
The Adtec SteriPlas is a topical antibacterial, cold plasma medical device with proven antibacterial efficacy, proven accelerated healing and a greater advantage over antibiotics for the treatment of wounds, surgical site infections and dermatological conditions.
It has been thoroughly tested in an array of clinical trials and publications to demonstrate its clinical efficacy with no side effects reported.
ADTEC Europe Ltd. sells this device.